Analog section
Excitation voltage 10V DC ±5%, Output current; within 120mA, remote sense type(Up to 4 loadcells at 350Ω are parallel-connectable.)
Zero adjustment range 0 to 1.5mV/V for HI gain0 to 3.0mV/V for LO gain (digital adjustment)Input of approx. 0.5mV/V or 1.0mV/V,Selectable adjust to zero [by dip switch on the rear panel]
Gain adjustment range 2 stages of gain selectable according to the output of loadcell [by dip switch on the rear panel]
0.5 to 1.5mV/V for HI gain
1.0 to 3.0mV/V for LO gain (digital adjustment)
Min. input sensitivity 0.5μV/count
Accuracy Non-linearity: within 0.01%/FSZero drift: within 0.2μV/°C RTI (Typ: 0.15μV/°C)Gain drift: within 15ppm/°C (Typ: 7ppm/°C)Noise: within 0.1μVp-p RTI (0.1 to 10 Hz)
Analog filter Bessel low-pass filter (-12dB/oct.)Selectable from 2, 4, 6, 8 Hz
A/D converter Speed: 100 times/sec.Resolution: 16 bit
Min. display resolution 1/10000
Secondary calibration Calibration can be carried out without an actual load by connecting a resistor to one of the bridges of a loadcell.
 
Setting section
Setting method ・ Keyboard operation (membrane switch with a key click buzzer)・ External setting is available by installing a setting point option or RS-232C option
Setting value storage ・ Initial set values: NOV RAM (Non-volatile RAM)・ Other set values: C-MOS RAM with backup of a lithium battery(Effective for more than 7 years depending on usage conditions and storage environment.)
Setting value protection Setting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction
Setting items ・ Upper Limit/ Lower Limit/ Near Zero/ Set Point 1/ Set Point 2/ CPS/ Over/ Under/ Final・ Comparison Inhibit Time/ Judging Time/ Complete Output Time/ Compensation Feeding Time/ Auto Zero Count/ Judging Count/ Auto Free Fall Compensation Regulation/ Preset Tare Weight・ Weighing Function 1/ Weighing Function 2/ Weighing Function 3/ Sequence Mode/ Function Key Disablement/ Filter/ Motion Detection/ Zero Tracking/ Setting Value Lock・ Balance Weight/ Capacity/ Min. Scale Division/ Over Net/ Over Gross/ DZ Regulation Value/ Function Selection/ Gravitational Acceleration/ Optional Board・ D/A Output Mode/ D/A Zero Output Weight Value/ D/A Full Scale/ RS-232C I/F・RS-485 I/F/ ID Number/ Set Point Interface/ External Function Selection/ Standard/NTEP Mode Selection・ Span Calibration/ Zero Calibration
 
I/O section
External output signal Transistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON (Near zero, SP1, SP2, SP3, go or comp, over, under, high limit, Low limit, stable, weight alarm or error, run)
External input signal ON when shorted to COM terminal by TTL-level relay, switch, transistor, or open collector output. (Feed / discharge, tare ON, tare OFF, zero, gross / net, hold or judgment, start, stop) (Drive current: 10mA or less)
Output Conditions – SP1: Net weight >= final weight-SP1– SP2: Net weight >= final weight-before final– SP3: Net weight >= final weight-FF– Under: Net weight < final weight-underweight– Over: Net weight > final weight-overweight– Go: Final weight+overweight >= netweight >= final weight-underweight
Interface ・ SIF: 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display.・ SPI: Interface for set-point units (Optional); Interface to enter various set values via digital switches.・ BCO: BCD parallel data output interface (Optional): Parallel interface to transmit weight data to a printer, external display, PC or sequencer.・ 232: RS-232C communication interface (Optional): Write (change)/read weight data, various statuses and setting values from a PC or sequencer.・ 485: RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F701 are parallel-connectable.・ DAC: D/A converter interface (Optional); Interface to convert weight data to current signal and output it.
 
Display section
Display unit Numerical display (7 digits) with a character height of 18.5mm by fluorescent display tube
Display value 5 digits, Minus sign displayed on most significant digit
Scale capacity 5-digit numerical values
Min. scale division 1 to 100
Decimal point Selectable from 0, 0.0, 0.00, 0.000 (with zero blanking function)
Over-scale display Input of A/D converter overflow,Net weight over the set net value,Scale capacity + 9 scale divisions,Gross weight over the set gross weight
Center zero True zero point or the center of each value is displayed.
Unit display Selectable from t, kg, g, N, lb, none
Status display SP3, SP2, SP1, LOCK, ZT, ZALM, STAB, TARE, NET, GROSS, HI LIM, HI, GO, LO, LO LIM, HOLD, NZ
 
General performance
Power supply voltage 85 to 110V, 102 to 132V, 170 to 220V, 187 to 242V AC(Please specify when ordering), 50/60 Hz
Power consumption 15VA
Operating conditions Temperature: Working temperature range -10°C to +40°C;Storage temperature range -20 to +85°CHumidity: 85% RH or less (non-condensing)
Dimensions 192(W)×96(H)×160(D) mm (protruding parts not included)
Panel cutout dimensions 186 +2 -0(W)×92 +1 -0(H)mm*Installation panel thickness: 1.6mm or more
Weight Approx. 2.2 kg